Valve selection

time:2014/11/23From:东洋阀门(上海)有限公司

Also known as a one-way check valve or check valve, and its role is to prevent the line of medium back. Pump suction bottom check valve also belong to the class.

Opening and closing pieces by medium flow and strength to turn itself on or off, in order to prevent the media called backflow check valve. Check valves are automatic valves, mainly used for one-way flow of media channels, only allowing media to flow in one direction, in order to prevent accidents.

Valve selection:

1, the check valve is generally applicable to clean media, not for the larger media containing solid particles and viscosity.

2, following the low pressure valve for DN50mm advised to use butterfly valve, check valve and diaphragm vertical lift check valve; For DN greater than 200mm, less than 1200mm in the low-pressure valve, should use no wear return valve on the ball; for DN greater than 50mm, less than 2000mm of low pressure check valve, butterfly valve and diaphragm should use check valves.

3, diaphragm-type check valve is suitable for pipeline easy to produce water, the membrane could be eliminated when the aqueous medium is countercurrent generated, but by the temperature and pressure limits, typically in low pressure at room temperature pipe

4, for the time required to close a relatively small impact on water or water pipe, should use slow gentle swing check valve closed butterfly valve closed.

5, for the pump inlet pipe, should use the bottom valve, foot valve generally only be installed on a vertical pipe pump inlet and bottom-up flow of the medium;

6. Lift the more swing tightness, large fluid resistance, should be installed in horizontal horizontal pipe, vertical mounted in a vertical pipe;

7, the installation location swing check valves are not limited, it can be installed in a horizontal, vertical or inclined pipeline, such as mounted in a vertical pipe, the flow of the medium to be from the bottom up;

8. Swing check valves should not be made of small caliber, can be made into a high working pressure, nominal pressure up to 42MPa, nominal diameter and can do a lot, more than the maximum you can reach 2000mm. Depending on the shell and seal material can be applied to any work in any medium and operating temperature range. Medium is water, steam, gas, corrosive media, oil, pharmaceuticals, and so on. Medium temperature range between -196--800 ℃.

 

Next:How to choose the cast steel gate valve stem
Last:Cut-off valve types and selection principles
东洋阀门(上海)有限公司
Tel:+086-021-51619764
Fax:+086-021-51619764
E-mail:toyo6789@163.com
Address:450 South Road, Fengxian District, Shanghai

东洋阀门(上海)有限公司
Tel:+86-021-51619764 Fax:+86-021-51619764 Email:toyo6789@163.com
Add:450 South Road, Fengxian District, Shanghai